What was found
CRACK BODY STATION 663.75 VAPOR BARRIER LBL10 APROX. AT MAIN WHEEL WELL COMPARTME / REPAIRED VAPOR BARRIER LH SIDE MAIN WHEEL WELL COMPARTMENT LOCATED BTW LBL 6.15 TO LBL 15.54 LOWER POSITION BS 663.75 DAMAGE SIZE L=6' W=0.03' ASPER B737-700 SRM 57-10-10-2R-2 REPAIR 2 PARAGRAPH 6 THIS IS AND INTERIM REPAIR AND REQUIRED A DETAILE DO AVISUAL INSPECTION ON THE REPAIR AREA AT 3000 FLIGHT CYCLES INTERVAKS IAW B737-700 SRM 57-10-10-2R-2 REPAIR 2 PAR 2C FOR INSPECTION REQUIREMENT SEE TLD S/N T080524