What was found
CREW REPORTED R/H FUSELAGE DENT AFT & BELOW THE FWD SERVICE DOOR ' 'FOUND DENT TO BE LOCATED BELOW STGR 18R; BS 351.0 MEASURING 3'L X 2'W X .062' D. W/Y = 32-25 AND DENT FOUND TO BE SMOOTH AND NOT WITHIN 1' OF A FASTENER. DENT FOUND TO BE WITHIN LIMITS PER SRM 53-00-01/1A01. NO FURTHER ACTION REQUIRED. DENT DOT APPLIED PER MPM 52-03-01-02 REF LP #00960751E FOR ACCOMPLISHMENT OF CONDITIONAL INSP. / C) REPETITIVE ACTION REQUIRED COMPLIED WITH. ADDITIONAL DAMAGE OR DETERIORATION WAS FOUND. CONDITION HAS BEEN CORRECTED AS NOTED ON EC DTI-53EA-07851