What was found
FWD CABIN WET AREA FLOOR STRUCTURE; STA 304-324; RBL50; WL209; THRESHOLD SUPPORT ANGLE UPPER SURFACE; CORROSION; MRK'D IN RED. / REMOVED CORROSION FROM FWD WET AREA THRESHOLD SUPPORT ANGLE IAW SRM 53-10-15-1A-2 AND INSPECTED W/ 10X MAG GLASS NO DEFECTS NOTED VERIFIED MATERIAL LOSS ORIGINAL T = .090' REMAINING T = .070' LOSS = .020' LIMITS = .009' FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-2 REMOVED AND REPLACED ANGLE IAW SRM 51-40-02-0G-0 AND DWG 141A8310 REV - P/N 141A8312-5 A TAG Y50147