What was found
FORWARD CARGO COMPARTMENT FLOOR STRUCTURE L/H ZEE ANGLE STA 500E TO 500I LBL 23 WL 156 HAS CORROSION / REMOVED CORROSION AT FWD CARGO COMPARTMENT FLOOR STRUCTURE L/H Z ANGLE STA 500E TO 500I LBL 23 IAW B 737 SRM 51-10-02-0G-0 ITEM 15 ORIGINAL 'T' .040 REMAINING .029 LOSS .011 THE DEEPEST AREA FOUND TO BE OUT OF LIMITS IAW B 737 SRM 53-00-53-1A-2 FIG 103 CUT OUT DAMAGE SECTION BETWEEN STA 500B - 500C FABRICATED INSTALLED REPAIR OF Z ANGLE FROM STA 500B TO 500I IAW B 737 SRM 53-00-53-2R-5 REPAIR 5 P/N 143A7501-187