What was found
FLOOR STRUCTURE AT RIGHT AFT LAV AFT OUTBD MOUNT FITTING HAS CORROSION / REPAIRED PER SRM 53-70-51-ZR-5 AND EA 21-153-01050.STA 947.5 FLOOR BEAM PART #147A5504 PER SRM 53-70-51-OI-1; ITEM 1; FIG4; TABLE 4
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR STRUCTURE AT RIGHT AFT LAV AFT OUTBD MOUNT FITTING HAS CORROSION / REPAIRED PER SRM 53-70-51-ZR-5 AND EA 21-153-01050.STA 947.5 FLOOR BEAM PART #147A5504 PER SRM 53-70-51-OI-1; ITEM 1; FIG4; TABLE 4