As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
***CORROSION*** ON FLOOR SUPPORT LOWER SIDE OF AFT FLANGE AT BS 947.5+3; RBL 46- RBL 48; WL 207 / CORROSION ON FLOOR SUPPORT BS947.5+3 RBL46-RBL48; WL207 REMOVED IN A 1' X 1' X .015' ORIGINAL THICKNESS .072' FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1 REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-40-02; SRM 51-40-05 AND DWG# 147A5760 REV - 88911U JAN12-21