What was found
CORROSION ON FORWARD CARGO BAY AFT BULKHEAD CENTER PANEL LOWER SUPPORT AT B.S. 500D; R.B.L. 25; W.L. 154. REMOVED CORROSION IAW SRM 51-10-02-0G-0, ORIGINAL THICKNESS WAS 0.071 IAW SRM 53-30-08-0I-0 IDENTIFICATION 1. MAX. MAT. LOSS, L=1.5'XW=1.5'XD=0.004' REMAINING THICKNESS 0.067' FOUND TO BE WITHIN LIMITS. REWORKED AREA IAW SRM 53-30-08-1A-1 ALLOWABLE DAMAGE 1. APPLIED CHEMICAL CONVERSION COATING, PRIMER & ENAMEL IAW SRM 51-20-01, SOPM 20-41-02 ON REWORKED AREA.