What was found
AFT CARGO PIT; RH FLOOR SHIELD HAS CORROSION; WL:156; RBL:22; STA: 767-787. REMOVED CORROSION ON AFT CARGO FORWARD FLOOR SHIELD ORIGINAL THICKNESS .050 REMAINING .030 REMOVED .020 SHIELD WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-60--15-1A-1 TOOL 36649 DUE 8-4-21; VERIFIED MEASUREMENTS; VERIFIED STEPS 1 & 2