What was found
CRACKED UPPER ATTACH ANGLE OF BS 663 LOWER COMPOSITE BULKHEAD AT RBL 8, WL 164. REMOVED FASTENERS ON REPAIR AREA IAW SRM 51-40-02-OG-0 & 57 10-10-2R-5, REPAIR 5, STEP 4 A & PERFORMED CUT OUT ON REPAIR AREA IAW SRM 57-10-10-2R-5, REPAIR 5, STEP 4 A, FIG 202, REPAIR 5, SHEET 4. HFEC ROTARY INSPECTED OPEN HOLES IN REPAIR AREA IAW NDT PART 6 51-00-00, PROCEDURE 16. NO CRACKS FOUND. REWORKED AREA & UNDERLYING STRUCTURE IAW SRM 57-10-10-2R-5, REPAIR 5, STEP 4D. FABRICATED A -1 REPLACEMENT ANGLE, & -2 SPLICE ANGLE.