What was found
***CORROSION*** ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B.S 500A-500D; R.B.L. 23; W.L. 154. / REMOVED AND INSTALLED ON FCB FLOOR TO SIDEWALL SUPPORT AT BS500A-500D RBL23 WL154 NEW FABRICATED FLOOR TO SIDEWALL SUPPORT FROM BAC1496-444 LOT 1457306-1 LOCATED AND DRILLED IAW SRM 51-40-05. APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01 AND AMM 51-21-72-370-804; SRM 53-30-53-01-02; SRM 51-40-02 AND DWG 143A7500 80641U 03MAY21