What was found
WING TO BODY FAIRING PANEL 194CL INNER SURFACE AREAS ARE CHAFED. CHAFING ALONG THE INNER EDGE BAND EXCEEDS THE ALLOWABLE LIMITS OF SRM 53-60-70-1A-1 PARA 4 B 3 A. REMOVED CHAFING DAMAGE FROM ALONG THE INNER EDGE BAND; CLEANED REPAIR AREA. FABRICATED REPAIR PLIES, INSTALLED PLIES, VACUUM BAGGED PLIES AND VERIFIED 5X5 AND SET PLIES TO CURE, UNBAGGED PLIES AND LIGHTLY SANDED IAW SRM 51-70-05-2R-6 PARA 4.A-G AND I. UT INSPECTED REPAIR PER NDTM PART 4; 51-00-02. NO DISBONDS NOTED. REFINISHED REPAIR AREA IAW SRM 51-70-05-2R-6 PARA 4 STEP I.