As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT CRACKED BS 344-360 BL0 WL 208 / REMOVED DAMAGED/CRACKED FLOOR SUPPORT INTERCOSTAL VERIFIED AS OUT OF LIMITS PER SRM 53-10-51-1A-1 CRACK WAS 1.3' LONG NOT AT AN EDGE. INSTALLED NEW INTERCOSTAL FLOOR SUPPORT AT BS344-360 BL0 WL208 IAW DWG 141A5400 ID:0032 REV:- FRAME 1 AND 2. 59736U 4/26/21 AND SRM 51-40-02.