What was found
FWD PIT STA 500+6' FLOOR SHIELD UPPER SURFACE CORRODED AT RBL 23 AND WL157. / REMOVED CORROSION FROM PIT STA 500+6' FLOOR SHEILD UPPER SURFACE AT RBL 23 AND WL 157; ORIGINAL THICKNESS .050' REMAINING .045' LOSS .005' NO ALLOWABLE LIMITS ON PART OUT OF LIMITS. BACK SHOP FORMED AND HEAT TREATED PART ON WORK ORDER # 41323-1400-0001 I/A/W BOEING DWG 143A8126 REV - FABRICATED NEW FLOOR SHEILD I/A/W BOEING 143A8125- REV.- REPLACED FLOOR SHEILD I/A/W 737-800 SRM 51-40-02-0G-0 AND BOEING DWG REV. -143A0080- REV - P/N 143A8126-38