What was found
FWD PIT STA 495 RBL24 FLOOR SUPPORT SHIELD UPPER SURFACE CORRODED AT WL157 / REMOVED CORROSION FROM FWD CARGO FLOOR SHIELD IAW SRM 51-10-02-0G-0 PAR 15 AND INSPECTED W/ 10X MAG GLASS VERIFIED MATERIAL LOSS TO BE = .005' ORIGINAL T = .032' LIMIT = .003' FOUND TO BE OUT OF LIMITS IAW SRM 53-30-15-1A-1 FIG 103 REMOVED AND REPLACED DAMAGED FLOOR SHIELD IAW SRM 51-40-02-0G-0 AND DWG 143A0080 REV - APPLIED CIC TO VAPOR AND LOWER SURFACE OF FLOOR SHIELD IAW AMM 51-21-91-620-802 P/N 143A8126-38 A TAG EY1689