What was found
CORROSION ON FORWARD CARGO BAY THRESHOLD SUB WEB AT B.S. 480+11; R.B.L. 25; W.L. 154. ; / THIS WORK CARD WILL BE ACCOMPLISHED ON WORD CARD NUMBER TTG8Q0051LSW; THIS WORK CARD WILL BE ACCOMPLISHED ON WORK CARD NUMBER TTG8Q0051LSW; COMPLETE; WORK TRANSFERRED. 1. YOVANY RODRIGUEZ (TECHNICIAN), 15-MAY-2021 16:46 UTC VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMIT ON THRESHOLD WEB IAW SRM 53-30-15-1A-1 AND 53-30-15-0I-1 ID. REMOVED CORROSION ON WEB, DIMENSION 1" X 1" IAW SRM 51-10-02 PARA. 15 AND FOUND OUT OF LIMITS DUE MATERIAL LOSS EXCEED 10% OF THICKNESS IAW SRM 53-30-15-1A-1, PART MUST BE REPLACED.