As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT B.S. 500A+10; L.B.L. 24; W.L 154. ; / INSTALLED ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT BTW B.S. 400-B.S.500D L.B.L. 24;W.L. 154 PER S.R.M. 51-40-02-0G-0 D.W.G #143A7501.; VERIFIED; INSTALLED ON FORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT BTW B.S. 400-B.S.500D L.B.L. 24;W.L. 154 PER S.R.M. 51-40-02-0G-0 D.W.G #143A7501.; INSPECTION COMPLETE