What was found
FWD CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT CRACKED AT FASTENER HOLE BS 500A LBL 21 WL 157 ; / VERIFIED APPLIED PRIMER ON FLOOR TO SIDEWALL SUPPORT AND SPLICE ANGLE PER AMM 51-21-72-370-801.; INSTALLED FLOOR TO SIDEWALL SUPPORT SPLICE ANGLE PER SRM 53-00-53-2R-6; SRM 51-40-02-0G-0.; VERIFIED INSTALLED FLOOR TO SIDEWALL SUPPORT SPLICE ANGLE PER SRM 53-00-53-2R-6; SRM 51-40-02-0G-0.