What was found
REJECTION-CORROSION REMOVAL ON FRAME AT AFT CARGO BAY BS 947; LBL 9; WL 178 REJECTED DUE TO OUT OF LIMITS PER SRM 53-70-07-1A-1 DETAIL C. DUE TO PROXIMITY TO FASTENER HOLES. ; (REJECTION FROM CUSTOMER CARD TTG8Q0050WTE) CORROSION REMOVAL ON FRAME AT AFT CARGO BAY BS 947; LBL 9; WL 178 REJECTED DUE TO OUT OF LIMITS PER SRM 53-70-07-1A-1 DETAIL C. DUE TO PROXIMITY TO FASTENER HOLES. BLEND IS COMMON TO INNER CHORD OVER TWO FASTENER HOLES / ACCOMPLISHED REPAIR ON FRAME AT AFT CARGO BAY BS 947; LBL 9; WL 178 IAW TC# 21-153-01477-WIP1 WAS DOCUMENTED ON TASK CARD TTG8Q0050WTE; VERIFIED ACCOMPLISHED REPAIR ON FRAME AT AFT CARGO BAY BS 947; LBL 9; WL 178 IAW TC# 21-153-01477-WIP1 WAS DOCUMENTED ON TASK CARD TTG8Q0050WTE.; ENSURE THAT ALL STEPS OF EA 21-153-01477-WIP1 HAVE BEEN COMPLETED AND SIGNED OFF