What was found
CORROSION ON INTERCOSTAL AT AFT CARGO BAY BS848 RBL6 WL158. ; / APPLIED A CHEMICAL CONVERSION COATING AND PRIMED NEW INTERCOSTAL IAW BOEING DWG 146A8132 OK TO INSTALL;CORRECTED ITEM 6 LOCATED AND DRILLED NEW INTERCOSTAL AT ACB BS847 - BS867 RBL6 WL158 IAW BOEING DWG 146A8130;CORRECTION FROM ITEM 6; LOCATED AND DRILLED NEW INTERCOSTAL AT BS847- BS867 RBL6 WL158 IAW BOEING DWG 146A8130;CORRECTION LOCATED AND DRILLED NEW INTERCOSTAL AT BS847-BS867 RBL 6 WL158 IAW BOEING DWG 146A8130;INSTALLED NEW INTERCOSTAL BS 847-867 ; RBL 6; WL 153 IAW SRM 51-40-02-0G-0; DWG# 146A8130;LOCATED AND DRILLED NEW INTERCOSTAL AT ACB BS848 RBL6 WL158 IAW BOEING DWG 146A8130;RECEIVED NEW ACB INTERCOSTAL FROM FAB ON P;O#824809-SWA;VERIFIED FAB PER DWG 146A8132-5 ON P.O #824809-SWA;VERIFIED HEAT IAW BAC5602 ON P.O#824809-SWA;REMOVED INTERCOSTAL BS 847-867 RBL6 WL 158 PER SRM 51-40-02-0G-0.;VERIFIED MEASUREMENT TABLE; INTERCOSTAL FOUND TO BE OUT OF LIMITS AND REPLACEMENT PART PER SRM 51-10-02-0G;CORRECTION FROM ITEM 6 LOCATED AND DRILLED NEW INTERCOSTAL AT BS847-BS867 RBL 6 WL158 IAW BOEING DWG 146A8130;EVALUATED CORROSION ON INTERCOSTAL BS848 RBL6 WL158 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;UPDATED MEASUREMENT TABLE;VERIFIED INSTALLATION OF NEW INTERCOSTAL BS 847-867 ; RBL 6; WL 153 IAW SRM 51-40-02-0G-0; DWG# 146A8130;VERIFIED STEPS 5; 6; AND 7 OK TO INSTALL