What was found
CORROSION ON ATTACH ANGLE AT AFT CARGO BAY BS727D+10 RBL6 WL151. ; / PRIMERED ATTACH ANGLE PER SRM 51-21-72-370-804; OK TO INSTALL.;REMOVED ATTACH ANGLE IN ACB BS727D+10 RBL6 WL151 IAW SRM 51-40-02.;REFERENCE ESR: 21-01944; FABRICATED ATTACH ANGLE BS 727D+ 10 RBL6 WL151; USING BAC1493-672#7075-T62; LOT #1370754-1 PER SRM 51-40-05-0G-0; DWG 146A7734; DWG 146A7730; APPLIED A CHEMICAL CONVERSION COATING PER AMM 51-21-41-370-802.;VERIFIED MEASUREMENT TABLE; ATTACH ANGLE FOUND TO BE OUT OF LIMITS AND REPLACEMENT PART PER SRM 51-10-02-0G;CORRECTION TO STEP 7; SHOULD BE AMM NOT SRM.;EVALUATED CORROSION ON ATTACH ANGLE BS727D+10 RBL6 WL151 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;INSTALLED ATTACH ANGLE BS 727D + 10 RBL6 WL 151 PER SRM 51-40-02-0G-0; DWG 146A7730.;REMOVED ENGINEERING ROW DUE TO ENGINEERING NOT REQUIRED;UPDATED MEASUREMENT TABLE;VERIFIED PRIMERED ATTACH ANGLE PER AMM 51-21-72-370-804; OK TO INSTALL.;VERIFIED INSTALL OF ATTACH ANGLE BS 727D + 10 RBL6 WL 151 PER SRM 51-40-02-0G-0; DWG 146A7730.;VERIFIED STEP 5.