What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN STA 312 TO STA 328 AT LEVEL RBL 31 AT FWD GALLEY AREA ; 2021-215606 / REPLACED WEB INTERCOSTAL AND FASTENER LOCATED BETWEEN STA 312 TO STA 328 AT LEVEL RBL 31 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 SRM 51-40-02 AND DWG 141A5400 SHEET 39 REV -;REPLACED WEB INTERCOSTAL AND FASTENER LOCATED BETWEEN STA 312 TO STA 328 AT LEVEL RBL 31 AT FWD GALLEY AREA; COMPLETED RII INSPECTION.;TOOL USED RADIUS GAUGE P/N: 5167C S/N AE-28532 DUE DATE 19-AUG-21;TOOL USED RADIUS GAUGE P/N 5167C S/N AE-28532 DUE DATE 19-AUG-21