What was found
CRACK INDICATION ON FORWARD GALLEY DOOR UPPER FORWARD CUTOUT CORNER STUB FRAME FASTENER HOLE. LOCATED AT BS 291.5 PLUS 6.75 INCH. AND 3 INCH. ABOVE STR9R AT UPPER FUSELAGE. ; 2021-215622 / REPLACED STUB FRAME AND FASTENERS LOCATED ON BS 294.5 BETWEEN STR 7R TO STR 10R IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DRAWING # 141A8370 SHEET 2 REV. C; REPLACED STUB FRAME AND FASTENERS LOCATED ON BS 294.5 BETWEEN STR 7R TO STR 10R IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DRAWING # 141A8370 SHEET 2 REV. C COMPLETE RII INSPECTION