What was found
CORROSION ON ACB FLOOR-TO-SIDEWALL SUPPORT WEB; BS 787-796; WL 160 ; / BLENDED CORROSION ON ACB FLOOR TO SIDEWALL SUPPORT WEB BS 787-792; RBL 22; WL 160. BLENDED 1'X1'X.020'; ORIGINAL THICKNESS IS .063'. FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1.;INSTALLED NEW ACB FLOOR TO SIDEWALL SUPPORT WEB BS 787-792; RBL 22; WL 160 IAW SRM 51-40-02-0G-0; DWG# 146A8320.;LOCATED; DRILLED; DEBURRED NEW ACB FLOOR TO SIDEWALL SUPPORT WEB BS 787-792; RBL 22; WL 160 IAW SRM 51-40-05-0G-0; DWG# 146A8320. OK TO INSTALL;REMOVED SUPPORT WEB BS 787-792; RBL 22; WL 160 IAW SRM 51-40-02-0G-0;VERIFIED LOCATE; DRILL; DEBURR OF NEW ACB FLOOR TO SIDEWALL SUPPORT WEB IAW SRM 51-40-02 AND DWG 146A8320<BR>OK TO INSTALL;VERIFIED SRM REFS AND OUT OF LIMITS STATEMENT; VERIFIED REMOVAL OF PART PER SRM 51-40-02;VERIFIED ALL WORK COMPLETE;VERIFIED INSTALLATION OF NEW ACB FLOOR TO SIDEWALL SUPPORT WEB BS 787-792; RBL 22; WL 160 IAW SRM 51-40-02; DWG# 146A8320.