What was found
**CORROSION** AFT CARGO DOOR SURROUND STRUCTURE FWD SHIELD SEVERAL CORROSION SPOTS NOTED (223 DOT 002) ; / (AMENDING STEP #9) LOCATED AND DRILLED HOLES ON NEW AFT CARGO DOOR FWD SHIELD ANGLE IAW SRM 51-40-05-0G-0 AND DWG #146A8127.;(AMENDING STEP 14) EVALUATED AREA: ORIGINAL MATERIAL 0.050'. MATERIAL REMOVED 0.007'. MATERIAL REMAINING 0.043' FOUND OUT OF LIMITS IAW SRM 53-60-15-1A-1. RECEIVED NEW AFT CARGO DOOR SURROUND STRUCTURE FWD SHIELD ANGLE; LOCATED AND DRILLED; TREATED AND PRIMED IAW SRM 51-20-01-0G-0; SRM 51-40-05-0G-0 AND DWG #146A8127. ANGLE WILL BE INSTALLED ON CUSTOMER CARD #TTG8Q004F476;CERTIFIED;EVALUATED AREA: ORIGINAL MATERIAL 0.050'. MATERIAL REMOVED 0.007'. MATERIAL REMAINING 0.043' FOUND OUT OF LIMITS IAW SRM 53-60-15-1A-1.;FINAL INSPECTED; AFT CARGO FWD CUTOUT SHIELD CORROSION REPAIRED (STEP #15).;LOCATED AND DRILLED HOLES ON NEW AFT CARGO DOOR FWD SHIELD ANGLE IAW SRM 51-40-05-0G-0.;NULLIFIED STATEMENT STEP #7 (ENTER IN ERROR).;OK TO TREAT AND PRIME.;PERFORMED UT THICKNESS INSP AT REWORKED AREA IAW B737 NDT P4 51-00-00 PROC.3; MIN THICKNESS NOTED 0.043' <BR>TOOL USED: OLYMPUS 27MG BC:172139;REMOVED CORROSION AT AFT CARGO DOOR SURROUND STRUCTURE FWD SHIELD IAW SRM 51-10-02-0G-0.;VERIFIED CORROSION REMOVAL; INSPECTED.;VERIFIED STEP #10; OK TO TREAT AND PRIME SHIELD ANGLE.