What was found
CORROSION AFT WET AREA FLOOR SUPPORT STRUCTURE (WEB) BETWEEN BS 1016 TO BS 1033 LBL-0 TO LB-L 19 SEVERAL SPOTS WITH SURFACE CORROSION MKD-126-05 ; / CERTIFIED REMOVED AND REPLACED SUPPORT WEB AT AFT WET AREA BETWEEN BS 1016 TO BS 1033 L/H. FINAL INSPECTION.;INSTALLED SUPPORT WEB AT AFT WET AREA BS 1016 TO BS 1033 L/H PER REF B737-700 SRM 51-40-02-OG-0 AND DWG#147A5620.;LOCATED AND DRILLED NEW SUPPORT WEB AT AFT CABIN BS 1016 LH PER REF B737-700 SRM 51-40-02-0G-0 AND DWG #147A5620;MIXED 0870C080BM654SK SEALANT AT 20:00 5/18/21.SQUEEZE OUT TIME BY 04:00 5/22/21.;PARTIALLY INSTALLED SUPPORT WEB AT AFT WET AREA L/H BS 1016 TO BS 1033 PER REF B737-700 SRM 51-40-02-0G-0 AND DWG#147A5620.;REMOVED AND REPLACED SUPPORT WEB AT AFT WET AREA BETWEEN BS 1016 TO BS 1033 L/H PER REF B737-700 SRM 51-40-02-0G-0 AND DWG#147A5620.;TREATED AND PRIMED NEW SUPPORT WEB PER REF B737-700 SRM 51-20-01-0G-0;VERIFIED PARTIAL INSTALLATION OF SUPPORT WEB L/H BS 1016 TO BS 1033; INSPECTED.;VERIFIED STEP#2. OK TO TREAT AND PRIME HOLES;VERIFIED SUPPORT WEB INSTALLATION AND 100% FASTENER INSTALLATION BY SQUEEZE OUT TIME; CERTIFIED STEPS #7; #8 AND #9.;REMOVED WEB AT AFT WET AREA BETWEEN BS 1016 TO BS 1033 LH PER REF B737-700 SRM 51-40-02-0G-0.;VERIFIED TREAT AND PRIME TO THE HOLES. OK TO INSTALL NEW SUPPORT WEB