What was found
***CORROSION*** ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT FWD CARGO BAY BS500D LBL20. ; WL157. / CARD COMPLETE;INSTALLED AFT BULKHEAD TO FLOOR SUPPORT ANGLE ATVFWD CARGO BAY BS500D LBL20 IAW DWG 143A9481; DWG 143A7902 AND SRM 51-40-02-0G-0;LOCATED; DRILLED DEBURRED NEW BULKHEAD TO FLOOR SUPPORT ANGLE BS 500D LBL 25 - RBL 25 PER SRM 51-40-05-0G-0; DWG 143A7902; DWG 143A9481.;OK TO INSTALL AFT BULKHEAD-TO-FLOOR SUPPORT; BS 500D; LBL 20;VERIFIED INSTALLATION OF AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT FWD CARGO BAY BS 500D LBL20 IAW DWG 143A9481; DWG 143A7902 AND SRM 51-40-02-0G-0;FWD CARGO BAY AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT BS500D LBL20 WL157 WAS FOUND OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM PART MUST BE REPLACED DUE TO SRM 51-10-02-OG-0 REMOVED BULKHEAD SUPPORT ANGLE AT BS500D FROM LBL25 TO RBL25 PER SRM 51-40-02;UPDATED PARTS TABLE;VERIFIED LOCATED; DRILLED DEBURRED NEW BULKHEAD TO FLOOR SUPPORT ANGLE BS 500D LBL 25 - RBL 25 PER SRM 51-40-05-0G-0; DWG 143A7902; DWG 143A9481;VERIFIED FWD CARGO BAY AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT BS500D LBL20 WL157 WAS FOUND OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM PART MUST BE REPLACED DUE TO SRM 51-10-02-OG-0 REMOVED BULKHEAD SUPPORT ANGLE AT BS500D FROM LBL25 TO RBL25 PER SRM 51-40-02