What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT AT AFT CARGO BAY BS947 LBL8 TO RBL20 WL179. ; / INSTALLED AFT BULKHEAD TO FLOOR SUPPORT IN ACB BS 947; LBL 8 TO RBL 20; WL 179 IAW SRM 51-40-02-0G-0; DWG# 149A8110; DWG# 149A8117.;LOCATED AND DRILLED NEW AFT BULKHEAD TO FLOOR SUPPORT AT AFT CARGO BAY BS947 LBL8 TO RBL20 WL179 IAW SRM 51-40-05-0G-0; OK TO INSTALL;OK TO INSTALL NEW BULKHEAD TO FLOOR SUPPORT ACB BS 947. LBL 8 TO RBL 20; WL 179;VERIFIED LOCATED AND DRILLED NEW AFT BULKHEAD TO FLOOR SUPPORT AT AFT CARGO BAY BS947 LBL8 TO RBL20 WL179 IAW SRM 51-40-05-0G-0; OK TO INSTALL;VERIFIED ALL WORK ACCOMPLISHED;VERIFIED CORROSION ON BS947 AFT BULKHEAD TO FLOOR SUPPORT IS OUT OF LIMITS AND REQUIRES REPLACEMENT DUE TO NO ALLOWABLE LIMITS IN THE SRM IAW SRM 51-10-02-0G-0.;VERIFIED INSTALLATION OF AFT BULKHEAD TO FLOOR SUPPORT IN ACB BS 947; LBL 8 TO RBL 20; WL 179 IAW SRM 51-40-02-0G-0; DWG# 149A8110; DWG# 149A8117.;CORRECTED REFERENCE SHOULD BE SRM51-10-02-0G-0;EVALUATED CORROSION ON BS947 AFT BULKHEAD TO FLOOR SUPPORT; FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0G-0;REMOVED ACB AFT BULKHEAD TO FLOOR SUPPORT BS 947 LBL8 TO RBL20 PER SRM 51-40-02-0G-0;UPDATED DAMAGE TABLE