What was found
CORROSION ON INTERCOSTAL AT AFT CARGO BAY BS946 LBL3 WL172. ; / INSTALLED NEW ACB INTERCOSTAL BS 927-947; LBL 3; WL 172 IAW SRM 51-40-02-0G-0; DWG# 147A7500.;LOCATED; DRILLED; DEBURRED; APPLIED CHEMICAL CONVERSION COATING; AND PRIMED; NEW ACB INTERCOSTAL BS 927-947; LBL 3; WL 172 IAW SRM 51-40-05-0G-0; DWG# 147A7500; DWG# 147A7580. OK TO INSTALL;RECEIVED FABRICATED INTERCOSTAL FROM OSS PO#824877.;VERIFIED DRILL UP; DEBURR; CONVERSION COATING; AND PRIMER APPLICATION. OK TO INSTALL.;VERIFIED MEASUREMENT TABLE; INTERCOSTAL FOUND TO BE OUT OF LIMITS AND REPLACEMENT PART PER SRM 51-10-02-0G;VERIFIED RECEIPT OF PART; MATERIAL AND TEMPER;EVALUATED CORROSION ON INTERCOSTAL AT BS946 LBL3 WL172 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;REMOVED INTERCOSTAL AT BS 947-927 LBL 3 WL 172 IAW SRM 51-40-02-0G-0;UPDATED MEASUREMENT TABLE;VERIFIED INSTALLATION OF NEW ACB INTERCOSTAL BS 927-947; LBL 3; WL 172 IAW SRM 51-40-02-0G-0; DWG# 147A7500.