What was found
CORROSION ON INTERCOSTAL AT AFT CARGO BAY BS928 RBL3 WL172. ; / INSTALLED NEW INTERCOSTAL ACB BS 927-947; RBL 3; WL 172 IAW SRM 51-40-02-0G-0; DWG# 147A7500.;LOCATED; DRILLED; AND DEBURRED NEW ACB INTERCOSTAL BS 927-947; RBL 3; WL 172 IAW SRM 51-40-05-0G-0; AND DWG# 147A7500. OK TO INSTALL;VERIFIED DRILL UP AND DEBURR. OK TO INSTALL;VERIFIED INSTALLATION OF INTERCOSTAL;EVALUATED CORROSION ON INTERCOASTAL AT BS928 RBL3 WL172 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;EVALUATION CONFIRMED;REMOVED INTERCOSTAL AT BS 947-927 RBL 3 WL 172 IAW SRM 51-40-02-0G-0;UPDATED MEASUREMENT TABLE