What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS887 - BS947 RBL22 WL170. ; / INSTALLED NEW FLOOR TO SIDEWALL SUPPORT ABC BS 887-947; RBL 22; WL 170 IAW SRM 51-40-02-0G-0; DWG# 147A7500.;OK TO INSTALL NEW FLOOR TO SIDEWALL SUPPORT;OK TO INSTALL NEW FLOOR TO SIDEWALL SUPPORT; BS 887-947; RBL 22; WL 170;REMOVAL AND REPLACEMENT OF FLOOR TO SIDEWALL SUPPORT COMPLETE;REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT BS 887-947 RBL 22; DEEPEST DEPTH AT BS 927 REMOVED 0.015 FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USED MICROMETER ID4566A S/N UNKNOWN;DAMAGE EVALUATED FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2;LOCATED AND DRILLED NEW ACB FLOOR TO SIDEWALL SUPPORT BS887 TO BS 947 RH IAW SRM 51-40-05-0G-0; SRM 51-40-02-0G-0 DWG 147A7500;REMOVED ACB FLOOR TO SIDEWALL SUPPORT BS887-947 PER SRM 51-40-02-0G-0;VERIFIED INSTALLATION OF FLOOR TO SIDEWALL SUPPORT PER DWG 147A7500;VERIFIED LOCATE AND DRILLED NEW ACB FLOOR TO SIDEWALL SUPPORT BS887 TO BS 947 RH IAW SRM 51-40-05-0G-0; SRM 51-40-02-0G-0 DWG 147A7500.