What was found
CORROSION ON BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS847 - BS867 LBL13 WL163. ; / CARD COMPLETE;OK TO INSTILL ANGLE;OK TO INSTILL ANGLE GIVEN;VERIFIED INSTALLED ACB BULKHEAD TO FLOOR SUPPORT ANGLE BS847 TO BS867LBL13 WL 163 IAW SRM51-40-02-0G-0 AND DWG 149A8102;CERTIFIED;CORRECTED BS FROM BS 887 TO BS867 ON CORRECTIVE ACTION #2;EVALUATED CORROSION ON BULKHEAD TO FLOOR SUPPORT ANGLE BS847 TO BS887 LBL13 WL163 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;EVALUATION CONFIRMED;INSTALLED ACB BULKHEAD TO FLOOR SUPPORT ANGLE BS847 TO BS867LBL13 WL 163 IAW SRM51-40-02-0G-0 AND DWG 149A8102;LOCATED AND DRILLED NEW BULKHEAD TO FLOOR SUPPORT ANGLE ACB BS847 TO BS867 LBL13 IAW SRM 51-40-05-0G-0 SRM 5140-02-0G-0 DWG149A8102;UPDATED MEASUREMENT TABLE;VERIFIED LOCATE AND DRILLED NEW BULKHEAD TO FLOOR SUPPORT ANGLE ACB BS847 TO BS867 LBL13 IAW SRM 51-40-05-0G-0 SRM 5140-02-0G-0 DWG149A8102