What was found
CRACKED WATER TANK SUPPORT ANGLE TO BS 947 BULKHEAD SUPPORT AT BS 947 LBL 11 WL 178 ; / INSTALLED NEW WATER TANK BULKHEAD SUPPORT ANGLE BS 947; LBL 11; WL 178 IAW SRM 51-40-02-0G-0; DWG# 149A8103.;LOCATED AND DRILLED NEW WATER TANK SUPPORT ANGLE TO BS947 BULKHEAD SUPPORT AT BS947 LBL11 WL178 IAW SRM 51-40-05-0G-0; OK TO INSTALL;VERIFIED LOCATED AND DRILLED NEW WATER TANK SUPPORT ANGLE TO BS947 BULKHEAD SUPPORT AT BS947 LBL11 WL178 IAW SRM 51-40-05-0G-0; OK TO INSTALL;VERIFIED ALL WORK COMPLETE;VERIFIED INSTALLATION OF NEW WATER TANK BULKHEAD SUPPORT ANGLE BS 947; LBL 11; WL 178 IAW SRM 51-40-02-0G-0; DWG# 149A8103;EVALUATED CRACK ON WATER TANK SUPPORT ANGLE FOUND TO BE OUT OF LIMITS FOUND OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS PER SRM 51-10-02-0G-0 REMOVED CRACKED ANGLE PER SRM 51-4-02-0G-0;UPDATED MEASUREMENT TABLE;VERIFIED