What was found
GUSSET AT BS 500D COMMON TO STR21L LBL58 WL178 IS CRACKED ; / VERIFIED ALL WORK ACCOMPLISHED THIS CARD;VERIFIED INSTALLATION OF NEW GUSSET AT BS 500D STR-21L IAW SRM 51-40-02-0G-0 AND DWG 143A7902.;VERIFIED LOCATE AND DRILL OF NEW GUSSET AT BS 500D STR- 21L IAW SRM 51-40-05-0G-0 AND DWG 143A7902<BR><BR>OK TO INSTALL;INSTALLED NEW GUSSET AT BS 500D STR-21L IAW SRM 51-40-02-0G-0 AND DWG 143A7902.;LOCATED AND DRILLED NEW GUSSET AT BS 500D STR- 21L IAW SRM 51-40-05-0G-0 AND DWG 143A7902; OK TO INSTALL.;REMOVED DAMAGED GUSSET AT BS 500D STR-21L IAW SRM 51-40-02-0G-0.;UPDATED MEASUREMENTS TABLE