What was found
GUSSET AT BS 500D COMMON TO STR22L LBL53 WL170 IS CRACKED ; / ACCOMPLISHED STEP 8.;INSTALLED NEW GUSSET AT BS500D STR22L LBL53 WL170 IAW SRM 51-40-02 AND DWG #143A7902.;LOCATED; DRILLED; DEBURRED; APPLIED CHEMICAL CONVERSION COATING AND PRIMERED NEW GUSSET AT BS500D STR22L LBL53 WL170 IAW SRM 51-40-05 AND DWG #143A7902.;OK TO INSTALL NEW GUSSET AT BS500D STR22L LBL53 WL170.;PERFORMED RII INSPECTION ON INSTALLATION OF GUSSET.;RECEIVED FORMED GUSSET FROM OSS; PO# 826080.;REMOVED GUSSET BS 500D AT STR. 22L LBL 53; WL 170 PER SRM 51-40-02-0G-0.;VERIFIED INSTALLED NEW GUSSET AT BS500D STR22L LBL53 WL170 IAW SRM 51-40-02 AND DWG #143A7902.;VERIFIED RECEIVED FORMED GUSSET FROM OSS; PO# 826080.;OK TO INSTALL GIVEN.;UPDATED MEASUREMENT TABLE