What was found
INTERCOSTAL WITH A CRACK ON UPPER SURFACE AT CABIN FLOOR STRUCTURE AT ABOUT BL-0 BETWEEN STA 344-360 ; / INSTALLED EWIS PROTECTION;LOCATED AND DRILL NEW INTERCOSTAL BETWEEN FS 344-360 BL 0;OK TO TREAT AND PRIME AREA;OK TO INSTALL INTERCOSTAL;REMOVED INTERCOSTAL BETWEEN FS 344-360 BL 0;;VERIFIED EWIS PROTECTION REMOVAL;VERIFIED INTERCOSTAL INSTALLATION;VERIFIED TREAT AND PRIME STEP;DOCUMENTED PARTS INSTALLATION;INSTALLED NEW INTERCOSTAL IN REF SRM 51-40-02-0G-0;AND DRAWING NUMBER 141A5400;REMOVED EWIS PROTECTION IN RED AMM 20-60-07-913-801;TREAT AND PRIMER HOLES AT INTERCOSTAL IN REF SRM 51-20-02-0G-0