What was found
CORROSION ON FWD CARGO DOOR SURROUND STRUCTURE; INTERNAL FWD VERTICAL STRAP; RBL30; BS440; WL160 ; AREA BY S-25R / [01] REMOVED CORROSION ON INNER FAIL SAFE STRAP AT B.S 440 RBL 30 WL 160; W 1.2' L 1.6' PER SRM 53-30-15-1A-1; [02] VERIFIED REMOVAL OF CORROSION ON INNER FAIL SAFE STRAP AT B.S 440 RBL 30 WL 160; W 1.2' L 1.6' PER SRM 53-30-15-1A-1; [03] UT THICKNESS TESTED BLENDED AREA PER 737NDT PART 4 51-00-00 PROCEDURE 2. LOWEST REMAINING THICKNESS IS .142'. CAL ID ATS2342 E650; [04] REMOVED VERTICAL STRAP AT BS 440; DUE WAS FOUND OUT OF LIMIT IAW SRM 51-40-02; [05] RECEIVED PART FROM OUT SIDE SERVICE MACHINE SHOP FABRICATION HFAB53-SP-012 (BAC1520-2799#7075T351) LOT#1196226 PER DRAWING 143A8206 IAW CUSTOMER RO NO. 826815-SWA JOB # 540270; [06] LOCATED AND DRILLED NEW VERTICAL STRAP AT FCB BS 440 RH IAW SRM 51-40-05-0G-0 AND DRAWING # 143A8206.<BR>OK TO TREAT AND PRIME; [07] CORRECTED ITEM 4; PART WAS FOUND OUT OF LIMIT IAW SRM 53-30-15-1A-1