What was found
AFT CARGO BAY FLOOR TRACK SPLICE ANGLE BS887 RBL 3 HAS CORROSION ; / [01] VERIFICATION APPLICABILITY NOT ALLOWABLE DAMAGE ITEMS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT. IAW SRM 51-10-02 STEP 9C; [02] VERIFIED APPLICABILITY NOT ALLOWABLE DAMAGE ITEMS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT. IAW SRM 51-10-02 STEP 9C; [03] REMOVED ON AFT CARGO BAY FLOOR TRACK SPLICE ANGLE B.S 887 RBL 3 IAW SRM 51-40-02; [04] LOCATED AND DRILLED NEW AFT CARGO BAY FLOOR TRACK SPLICE ANGLE B.S 887 RBL 3 IAW SRM 51-40-05-0G-0 AND DRAWING # 146A7506.<BR>OK TO INSTALL; [05] VERIFIED LOCATE AND DRILL OF NEW AFT CARGO BAY FLOOR TRACK SPLICE ANGLE B.S 887 RBL 3 IAW SRM 51-40-05-0G-0 AND DRAWING # 146A7506. <BR>OK TO INSTALL; [06] INSTALLED NEW AFT CARGO BAY FLOOR TRACK SPLICE ANGLE B.S 887 RBL 3 IAW SRM 51-40-02-0G-0 AND DRAWING # 146A7506; [07] INSTALLED NEW AFT CARGO BAY FLOOR TRACK SPLICE ANGLE B.S 887 RBL 3 IAW SRM 51-40-02-0G-0 AND DRAWING # 146A7506; 147A7500; [08] VERIFIED INSTALLATION OF NEW AFT CARGO BAY FLOOR TRACK SPLICE ANGLE B.S 887 RBL 3 IAW SRM 51-40-02-0G-0 AND DRAWING # 146A7506; #147A7500; [09] VERIFIED COMPLETION OF CARD