What was found
AFT CARGO BAY FLOOR TRACK SPLICE ANGLE BS887 LBL 3 ; / [01] VERIFICATION APPLICABILITY ON SRM NOT ALLOWABLE DAMAGE ITEMS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C; [02] VERIFIED APPLICABILITY ON SRM NOT ALLOWABLE DAMAGE ITEMS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C; [03] REMOVED ON AFT CARGO BAY FLOOR TRACK SPLICE ANGLE B.S 887 LBL 3 IAW SRM 51-40-02; [04] LOCATED AND DRILLED NEW ACB FLOOR TRACK SPLICE ANGLE BS 887 LBL 3 IAW SRM 51-40-05-0G-0 AND DRAWING #146A7506<BR>OK TO INSTALL; [05] REMOVED ON AFT CARGO BAY FLOOR TRACK SPLICE ANGLE B.S 887 LBL 3 IAW SRM 51-40-02; [06] LOCATED AND DRILLED NEW ACB FLOOR TRACK SPLICE ANGLE BS 887 LBL 3 IAW SRM 51-40-05-0G-0 AND DRAWING #146A7506