What was found
CRACKED FLOOR SUPPORT AT B.S. 540; B.L.0 - R.B.L. 24.5; W.L. 208.1. ; / [01] REMOVED FLOOR SUPPORT FROM BS 540 BETWEEN BL 0 AND LBL 24.5; WL 208.1 IAW SRM 51-40-02-0G-0; [02] REMOVED FLOOR SUPPORT FROM BS 540 BETWEEN BL 0 AND RBL 24.5; WL 208.1 IAW SRM 51-40-02-0G-0; [03] LOCATED AND DRILLED FLOOR SUPPORT P/N 143A5240-36 AT BS 540 BL 0 TO RBL 24.5; WL 208.1 IAW SRM 51-40-05-0G-0 AND DWG 143A0060 REV A; [04] OK TO INSTALL FLOOR SUPPORT AT BS 540 BL 0 - RBL 24.5 ; WL 208.1; [05] VERIFIED FLOOR SUPPORT P/N 143A5240-36 AT BS 540 BL 0 TO RBL 24.5; WL 208.1 IS LOCATED AND DRILLED IAW SRM 51-40-05-0G-0 AND DWG 143A0060 REV A. OK TO INSTALL; [06] INSTALLED FLOOR SUPPORT AT BS 540; BL 0 - RBL 24.5; WL 208.1 IAW SRM 51-40-02 AND DWG 143A0060 REV A.; [07] VERIFIED INSTALLATION OF FLOOR SUPPORT AT BS 540; BL 0 - RBL 24.5; WL 208.1 IAW SRM 51-40-02 AND DWG 143A0060 REV A.; [08] VERIFIED INSTALLATION OF FLOOR SUPPORT AT BS 540; BL 0 - RBL 24.5; WL 208.1 IAW SRM 51-40-02 AND DWG 143A0060 REV A.; [09] VERIFIED CARD COMPLETE