What was found
CRACKED FLOOR SUPPORT AT B.S. 540; B.L.0 - L.B.L. 24.5; W.L. 208.1. ; / [01] REMOVED FLOOR SUPPORT AT BS 540 ; BL 0 - LBL 24.5; WL 208.1 IAW SRM 51-40-02; [02] LOCATED AND DRILLED FLOOR SUPPORT P/N 143A5240-35 AT BS 540; BL 0 TO LBL 24.5; WL 208.1 IAW SRM 51-40-05-0G-0 AND DWG 143A0060; [03] OK TO INSTALL FLOOR SUPPORT BS 540; BL 0 TO LBL 24.5; WL 208.1; [04] VERIFIED FLOOR SUPPORT P/N 143A5240-35 AT BS 540; BL 0 TO LBL 24.5; WL 208.1 IS LOCATED AND DRILLED IAW SRM 51-40-05-0G-0 AND DWG 143A0060. OK TO INSTALL; [05] INSTALLED FLOOR SUPPORT AT BS 540; BL 0 - LBL 24.5 ; WL 208.1 IAW SRM 51-40-02 AND DWG 143A0060 REV A; [06] VERIFIED INSTALLATION OF FLOOR SUPPORT AT BS 540; BL 0 - LBL 24.5 ; WL 208.1 IAW SRM 51-40-02 AND DWG 143A0060 REV A; [07] VERIFIED CARD COMPLETE