What was found
R/H FWD SKATE ANGLE BS 1006 TO BS 1016 IS CHAFED. ; / [01] DAMAGE FOUND ON R/H FWD SKATE ANGLE BS 1006 TO BS 1016 P/N 147A3200-12 FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT ON SRM PARTS WILL REPAIR BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR-9C; [02] REMOVED R/H FWD SKATE ANGLE BS 1006 TO BS 1016 P/N 147A3200-12 IAW SRM 51-40-02-0G-0; [03] VERIFIED DAMAGE FOUND ON R/H FWD SKATE ANGLE BS 1006 TO BS 1016 P/N 147A3200-12 FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT ON SRM PARTS WILL REPAIR BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR-9C; [04] LOCATED AND DRILLED RH FWD SKATE ANGLE AT BS 1006 TO BS 1016 P/N 147A3200-12 LOT#1455572-4 IAW SRM 51-40-05-0G-0 AND DWG# 147A0030 OK TO INSTALL; [05] INSTALLED R/H FWD SKATE ANGLE FROM BS1006-BS1016 IAW SRM 51-40-02; IAW DWG#147AA0030 AND IAW DWG#147A0070; [06] VERIFIED INSTALLION R/H FWD SKATE ANGLE FROM BS1006-BS1016 IAW SRM 51-40-02; IAW DWG#147AA0030 AND IAW DWG#147A0070; [07] OK TO INSTALL R/H SKATE ANGLE; [08] VERIFIED ALL RII STEPS PREVIOUSLY COMPLETED AND INSPECTED; [09] VERIFIED ALL TASK STEPS COMPLETED AND INSPECTED