What was found
AFT CARGO FLOOR SUPPORT 'Z' CHANNEL IS CORRODED AT 727A TO 847 S25L DOT # 3 ; / [01] REMOVED CORROSION AT Z CHANNEL STA 727A TO 847 S25 L PER REF B 737 - 700 SRM 51-10-02-0G-0; [02] JOB CERTIFIED; [03] VERIFIED REMOVAL CORROSION AT Z CHANNEL ; PENDING NDT; [04] PERFORMED UT THICKNESS INSP AT REWORKED AREA IAW B737 NDT P4 51-00-00 PROC.3; MIN THICKNESS NOTED 0.025'<BR>TOOL USED OLYMPUS 27MG BC:172139; [05] EVALUATE REWORKED AREA: ORIGINAL THICKNESS .040'; MATERIAL LOST .015'; MATERIAL REMAINING .025'. FOUND OUT OF LIMIT AS PER REF B737-700 SRM 53-00-53-1A-2; [06] VERIFIED MATERIAL LOSS IN REWORK AREA PER SRM 53-00-53. FABRICATION REQUIRED; [07] LOCATED; DRILLED AND FABRICATED AFT CARGO FLOOR 'Z' CHANEL AT STA 727A TO 847 S25L AS PER REF B737-700 SRM 51-40-05-0G-0; [08] VERIFIED. JOB ACCOMPLISHED. OK TO TREAT AND PRIMER; [09] TREADED AND PRIMED AFT CARGO FLOOR SUPPORT Z CHANEL AS PER REF B737-700 AMM 51-21-41-370-801; [10] VERIFIED TREAT AND PRIMER ;OK TO INSTALL NUTPLATE AND ANGLES; [11] ACCOMPLISHED CHART; [12] INSTALLED NUT PLATE AT ZEE CHANNEL AS PER REF 737-700 SRM 51-40-02; [13] CERTIFIED NUT-PLATES INSTALLATION; [14] VERIFIED NUT PLATE INSTALLATION.; [15] REMOVED CORROSION AFT CARGO FLOOR 'Z' CHANEL AT STA 727A TO 847 S25L. FOUND OUT OF LIMITS; FABRICATED AS PER REF B737-700 SRM 51-40-05-0G-0.; [16] VERIFIED WORK ACCOMPLISHED