What was found
FLOOR STRUCTURE INTERCOSTAL CRACKED AT FASTENER HOLES BETWEEN STA 285.62 AND 294.5 BL0 ; / [01] EVALUATE DAMAGE AND VERIFIED P/N; [02] APPLIED EWIS PROTECTION AT AREA OF INTERCOSTAL PER B737-700 AMM 20-60-07-913-801.; [03] REMOVED CRACKER INTERCOSTAL PER B737-700 SRM 51-40-02-0G-0.; [04] VERIFIED REMOVAL OF CRACKED INTERCOSTAL BETWEEN STA 285.62 AND 294.5 BL0.; [05] LOCATED AND DRILLED NEW INTERCOSTAL PER B737-700 SRM 51-10-02-0G-0; [06] OK TO INSTALL NEW INTERCOSTAL RII; [07] OK TO INSTALL NEW INTERCOSTAL RII; [08] OK TO INSTALL; [09] INSTALLED INTERCOSTAL BETWEEN STA 285.62 AND 294.5 BL0 PER B737-700 SRM 51-40-02-0G-0 AND DRWG# 141A5400.; [10] VERIFIED INSTALLATION INTERCOSTAL BETWEEN STA 285.62 AND 294.5 BL0 PER B737-700 SRM 51-40-02-0G-0 AND DRWG# 141A5400.; [11] STEP 9 LATE ENTRY; AFTER INSTALLATION OF INTERCOSTAL; REMOVED EWIS PROTECTION PER B737AMM 20-60-07-913-801; [12] CERTIFIED EWIS PROTECTION REMOVAL