What was found
A22-33; FWD PIT FLOOR PANEL 120AF; 3 EDGES OF UPPER SURFACE; CORROSION; (SECONDARY STRUCTURE) ; / [01] VERIFIED MATERIAL AS 2024-T3- .071.IAW AMM 25-52-01-201-801. A-TAG # A30648; [02] C/W STEP 1; [03] BEGAN FABRICATING FLOOR PANEL 140AF. IAW AMM 25-52-01-201-801.; [04] VERIFIED STEP 3; [05] FABRICATED REPLACEMENT FWD PIT FLOOR PANEL 120AF; VERIFIED MATERIAL AS 2024-T3-.071. A-TAG# A30648. IAW AMM 25-52-01-201-801.; [06] C/W STEP 5<BR>AUDIT C/W