What was found
BROKEN LAVATORY B EMERGENCY EXIT LIGHT ASSY AT AFT GALLEY AREA ; 2021-257786 / [01] REPLACED LAVATORY B EMERGENCY EXIT LIGHT ASSY AT AFT GALLEY AREA IAW B737-700 AMM 33-51-01-960-801; [02] REPLACED LAVATORY B EMERGENCY EXIT LIGHT ASSY AT AFT GALLEY AREA IAW B737-700 AMM 33-51-01-960-801. OPERATIONAL TEST IS OK.; [03] TASK COMPLETED.<BR><BR>REPLACED LAVATORY B EMERGENCY EXIT LIGHT ASSY AT AFT GALLEY AREA AND PERFORMED OPERATIONAL TEST IS OK.