CRACK ANGLE FLOOR STRUCTURE LOCATED ON BS 693 AT LEVEL RBL 24.5 CENTER SECTION ; 2021- 257907 / [01] REPLACED ANGLE FLOOR STRUCTURE LOCATED ON BS 693 AT LEVEL OF RBL 2R.5 CENTER SECTION IAW SRM B737-700 51-40-02; SRM B737-700 51-10-02 ITEM 9 AND DWG # 273A9112 REV - MATERIAL USED BAC1490-2782 7075-0 HEAT TREATED TO T73 IAW BAC5602; [02] TASK COMPLETED VERIFIED AS RII <BR><BR>REPLACED ANGLE FLOOR STRUCTURE LOCATED ON BS 693 AT LEVEL OF RBL 2R.5 CENTER SECTION IAW SRM B737-700 51-40-02; SRM B737-700 51-10-02 ITEM 9 AND DWG # 273A9112 REV - .