What was found
REPAIR BS 663 L/H VAPOR BARRIER LBL 31.83 WL 157 ; / [01] IDENTIFIED L/H VAPOR BARRIER<BR>IAW SRM 57-10-10-0I-2 FIGURE2; TABLE 2 ITEM 4<BR>FOUND DAMAGE TO EXCEED ALLOWABLE LIMITS<BR>IAW SRM 57-10-10-1A-2 PARA 4 D 4 (B)<BR><BR>REPAIR TO BE EFFECTED IAW SRM 51-70-04-2R-10;<BR>PER SRM 57-10-10-2R-2 PARA 1 C. NOTE<BR><BR>REMOVED DAMAGE; PREPARED AND CLEANED REPAIR AREA.<BR>IAW SRM 51-70-04-2R-10 PARA 4 A; B; & C; [02] VALIDATED APPLICABILITY OF REPAIR SRM 51-70-04-2R-10.; [03] VERIFIED DAMAGE REMOVAL AND APPLICABILITY; [04] FABRICATED REPAIR PLIES FROM BMS9-3 STYLE 1581 TYPE H2 LOT#1458851-1 IAW SRM 51-70-05-2R-10 PARA 4 STEP D. OK TO INSTALL REPAIR PLIES.; [05] VERIFIED FABRICATION OF PLIES. OK TO INSTALL; [06] INSTALLED REPAIR PLIES WITH BMS8-301 CLASS 1 LOT#JH1CAA0868; VACUUM BAGGED REPAIR PLIES; VERIFIED 5X5 WAS GOOD AND SET PLIES TO CURE USING HOTBONDER ID:ATS532 S/N: 15092117 IAW SRM 51-70-04-2R-10 PARA 4.D-F.; [07] ACTION STEP 4 SHOULD READ 'IAW SRM 51-70-04-2R-10'; [08] VERIFIED CORRECTIVE ACTION #6 AND #7; SRM 51-70-04-2R-10 IS CORRECT REFERENCE FOR ACTION STEP #4.; [09] CURED REPAIR PLIES; UN-BAGGED; LIGHTLY SANDED AND TRIMMED EDGE IAW SRM 51-70-04-2R-10 PARA 4.F.; [10] CERTIFIED CURED REPAIR PLIES; UN-BAGGED; LIGHTLY SANDED AND TRIMMED EDGE IAW SRM 51-70-04-2R-10 PARA 4.F.; [15] REPAIRED BS 663 L/H VAPOR BARRIER LBL 31.83 WL 157 IAW SRM 51-70-04-2R-10;