What was found
FLOOR PANEL 242DF HAS PULLED FIBERS ON L/E ; / [01] DUE TO AMOUNT OF ALL DAMAGE FLOOR PANEL 242DF WITH PULLED FIBERS ON LEADING EDGE WAS REPLACED WITH A SERVICEABLE BOARD FABRICATED FROM BMS4-23 REV F TY II; LOT# 1450723-2. ALL INSERTS WERE INSTALLED USING BMS5-107 CL1 LOT# AK0DP4051K. PART MARKED PANEL IAW SRM 53-00-50-2R-0 PARA 1.A. (NOTE). AND 5.S. AND BOEING DWG# 144A5810-123.<BR><BR>THERMOMETER: ID: ATS2209 S/N: 43300739WS; [02] ADDING TO LINE 1; <BR><BR>INSERT P/N: SL5107A3-410<BR>APPLIED TAPE TO MATING SURFACE USING BMS8-283K TY1 LOT# 0NCO43865 IAW BOEING DWG 144A58810 SH.125; [03] FIXED LINE 2; <BR><BR>BOEING DWG# 144A58810 SH.123; [04] CORRECTION FOR LINES 2 & 3; DWG 114A5810; [05] CERTIFYING FABRICATION OF FLOORBOARD 242DF IAW SRM 53-00-50-2R-0 AND DRAWING 144A5810; [06] VERIFIED FABRICATION OF FLOORBOARD 242DF IAW SRM 53-00-50-2R-0 AND DRAWING 144A5810