What was found
B.S. 663 LOWER COMPOSITE BULKHEAD UPPER SUPPORT ANGLE IS CRACKED AT R.B.L. 8; W.L. 164. ; / [01] INSTALLED EWIS PROCTECTION AT REPAIR AREA PER AMM 20-60-07; AND REMOVED FASTENERS PER SRM 51-40-02-0G-0; [02] VERIFIED ITEM 1.; [03] CONFORMED -1 REPLACEMENT ANGLE AND -2 SPLICE ANGLE PER SRM 57-10-10-2R -1 REPLACEMENT ANGLE FABRICATED IN ACCORDANCE WITH SRM 57-10-10-2R REPAIR 5 REFER TO ATS BUILD RECORD ATSHFAB-101-354 JOB # 539510; -2 SPLICE SPLICE ANGLE FABRICATED IN ACCORDANCE WITH SRM 57-10-10-2R R; [17] REMOVED EWIS PROTECTION OF REPAIR AREA BS 663 RBL 6-39 IAW AMM 20-60-07-913-801; [18] VERIFIED APPLIED SEALING AROUND AND CIC AT REPAIR AREA BS663 RBL 6-18 WL 164 IAW SRM 57-10-10-2R-5. AND REMOVED EWIS PROTECTION OF REPAIR AREA BS 663 RBL 6-39 IAW AMM 20-60-07-913-801; [19] FUEL TANK CAP SEALING OF FASTENERS COMMON TO REPAIR AND LEAK CHECK OF FASTENERS WILL BE ACCOMPLISHED ON FAULT # TTG8Q00588KK; [20] VERIFIED FUEL TANK CAP SEALING OF FASTENERS COMMON TO REPAIR AND LEAK CHECK OF FASTENERS WILL BE ACCOMPLISHED ON FAULT # TTG8Q00588KK.