What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS867 RBL20 WL165. ; / [01] EVALUATED CORROSION; FOUND 0.020 REMOVED FROM ORIG 0.040 IN 1'X1' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING MICROMETER P/N 4566A S/N UNKOWN; [02] VERIFIED EVALUATED CORROSION; FOUND 0.020 REMOVED FROM ORIG 0.040 IN 1'X1' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING MICROMETER P/N 4566A S/N UNKOWN; [03] REMOVED ACB FLOOR TO SIDEWALL SUPPORT AT BS867 - BS887 PER SRM 51-40-02-0G-0; [04] LOCATED AND DRILLED ACB SIDEWALL SUPPORT BS 867-887; RBL 20 PER SRM 51-40-05; DWG# 146A7500; [05] VERIFIED LOCATED AND DRILLED ACB SIDEWALL SUPPORT BS 867-887; RBL 20 PER SRM 51-40-05; DWG# 146A7500; [06] OK TO INSTALL FLOOR TO SIDEWALL SUPPORT; [07] OK TO INSTALL; [08] INSTALLED ACB FLOOR TO SIDEWALL SUPPORT AT BS867- BS887; RBL20; WL 156 PER SRM 51-40-02-OG-O AND DGW 146A7500; [09] ADDED DWG 147A0060; [10] VERIFIED INSTALLATION OF ACB FLOOR-TO-SIDEWALL SUPPORT; BS 867-887; RBL20; WL 156; PER SRM 51-40-02-OG-O; DGW 146A7500; AND DWG 147A0060; [11] COMPLETED; [12] VERIFIED COMPLETION OF ALL WORK THIS TASK